Vitodens 100 B1HE/B1KE | Installation & Start Up/Commissioning

Products:

Vitodens 100 B1HE/B1KE, OneBase Digital Tools

  • Intermediate
  • 12 Modules
  • 8:50 hours

Course Overview

This class is for licensed contractors or service technicians that are beginning to or have been working with the Vitodens 100 B1HE/B1KE. This class will cover detailed information on all aspects of the installation (mounting, piping, venting, gas supply, wiring, programming) and boiler startup. There will be hands on portions for control programming and boiler commissioning. Prior experience with condensing boiler installations or service is required.

Standard Modules

  • 10 Modules
  • 6:50 hours
Control Programming Exercises | Vitodens 100 B1HE/B1KEIntermediate
Log In

Log in to request courses

Hands On Training (including but not limited to):

  1. Adjust DHW time programs
  2. Access Diagnostic Menu and show inputs
  3. Access the actuator tests and engage high and low fire/move the three way valve
  4. Access the heating curve
  5. Access the fault history
  6. Introduce and acknowledge a fault
Start-up / Commissioning Exercises | Vitodens 100B1HE/KEIntermediate
Log In

Log in to request courses

Hands On Training (including but not limited to):

  1. Commission boiler with HMI & Viguide
  2. Commission & wire boiler based on an application in the application guide
  3. Illustrate the benefits of Filling and Purging procedures
  4. Prime the condensate trap
  5. Perform static and dynamic gas pressure testing
  6. Perform combustion analysis
Venting | Vitodens 100 B1HE/B1KEIntermediate
Log In

Log in to request courses

Learning Objectives: 

  1. Identify Approved Venting Materials & Methods
  2. Explain Maximum Equivalent Vent Length Calculations
  3. Describe Venting Best Practices
  4. Discuss Exhaust Gas Recirculation and How to Avoid It
Gas Supply & Burner | Vitodens 100 B1HE/KE Intermediate
Log In

Log in to request courses

Learning Objectives: 

  1. Identify Gas Quality & Pressure Ranges for Vitodens 100 B1HE/KE
  2. Explain the Procedure to Switch Between Natural Gas and LPG
  3. Discuss the Matrix Plus Cylinder Burner
  4. Illustrate Proper Combustion Analysis Procedure
One Base Digital ToolsEntry
Log In

Log in to request courses

Learning Objectives: 

  1. Understand the Viessmann Account Structure and its functions
  2. Identify the available One Base Digital Apps and their benefits
  3. Describe the difference of residential and commercial boiler owner remote monitoring
  4. Describe the common method for contractors to remote monitor installations



Start Up & Commissioning | Vitodens 100 B1HE/KEIntermediate
Log In

Log in to request courses

The purpose of this course is to build a deeper understanding of the Vitodens 100 B1HE/B1KE Start up & Commissioning.

Learning Objectives: 

  1. Explain the Procedure to Effectively Purge Air out of the Boiler
  2. Contrast HMI & ViGuide Commissioning
  3. Describe the Benefits of ViCare
  4. Describe Gas Pressure Check & Combustion Analysis Procedures
Control Interface & Basic Programming | Vitodens 100 B1HE/KEIntermediate
Log In

Log in to request courses

Learning Objectives:

  1. Identify the Control Display Symbols & List Menu Overview
  2. Contrast Basic HMI & ViGuide Programming Procedures
  3. Describe Commonly Accessed Coding Parameters
Introduction | Vitodens 100 B1HE/B1KE Introduction
Log In

Log in to request courses

The purpose of the course is to build awareness of the Vitodens B1HE and B1KE models.

Learning Objectives: 

  1. Explain why the Vitodens 100 B1HE/KE is ideal for all space heating and DHW in condominiums and single-family homes
  2. Identify the digital connectivity and remote monitoring available for the Vitodens 100 B1HE/KE


Wiring | Vitodens 100 B1HE/KE Intermediate
Log In

Log in to request courses

Learning Objectives: 

  1. Describe the Process to Access Vitodens 100 B1HE/KE Wiring Connections
  2. Identify Vitodens 100 B1HE/KE Wiring Connections & Sensors
  3. Describe Typical Wiring Applications for the Vitodens 100 B1HE/KE
  4. Explain the Installation of a Low Water Cutoff
Mounting & Piping | Vitodens 100 B1HE/B1KE Intermediate
Log In

Log in to request courses

Learning Objectives: 

  1. Identify Mounting Options for Vitodens 100 B1HE/KE Boilers
  2. Examine the Benefits of the Four Pipe Design
  3. Explain the Reason for Primary Secondary Piping and the Benefits of Using a Low Loss Header vs. Closely Spaced Tees
  4. Explain why a Condensate Neutralizer is Essential and How to Avoid Condensate Backup


Add-on Modules

  • 2 Modules
  • 2 hours
Vitocell Indirect Tank | Vitodens 100 B1HEIntermediate
Log In

Log in to request courses

Learning Objectives: 

  1. Understand the Benefits of a Vitodens 100 B1HE with Vitocell Indirect vs a Combi
  2. Identify the Viessmann Indirect Family
  3. Explain the Advantages of Piping Strategies and Pipe Sizing
  4. Illustrate Peak Hourly Demand Sizing Method in Relation to Tank Performance


Service & Maintenance | Vitodens 100 B1HE/KE Intermediate
Log In

Log in to request courses

Learning Objectives: 

  1. State the Viessmann recommended service interval & control setup that result in a maintenance alert
  2. Describe the annual service procedure as outlined in the Viessmann service manual
  3. List the recommended chemicals and tools to clean the heat exchanger
  4. Illustrate a proper combustion analysis


Products Covered in this Training
  • Vitodens 100 B1HE/B1KE
  • OneBase Digital Tools